Live intelligence aggregated from the world's leading cybersecurity advisory bodies and researchers. Updated every 30 minutes.
View CSAF Summary Successful exploitation of these vulnerabilities could allow a non-privileged user to escalate privileges or view the credentials of other users. The following versions of Weintek cMT3092X are affected: cMT3092X firmware <20210218 EasyWeb <v2.1.20 ...
View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to write arbitrary files to restricted system directories outside of the application's intended directory. The following versions of Rockwell Automation ThinManager are affected:...
Russian State-Supported Cyber Actors Conduct Phishing Campaign Targeting Users of Zimbra Collaboration Suite Executive summary A group of Russian state-supported cyber actors has been targeting and compromising various Western government and commercial organizations using t...
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker obtaining confidential information from the device. The following versions of Johnson Controls XAAP Android are affected: XAAP Android <1.53 CVSS Vendor Equipment Vulnerabilities ...
View CSAF Summary Successful exploitation of these vulnerabilities could allow an unauthenticated network-adjacent attacker to crash critical IEC 61850 services or execute arbitrary code, disrupting or compromising protection, visibility, and control functions. The following vers...
View CSAF Summary Successful exploitation of this vulnerability could cause the parsing process to crash, which will cause a denial of service. The following versions of MZ Automation lib60870 are affected: lib60870 <=2.4.0 CVSS Vendor Equipment Vulnerabilities v3 8....
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with network access to achieve remote code execution. The following versions of Johnson Controls C-CURE 9000 and Victor application server are affected: C-CURE 9000 and victor <=v2.90_v...
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with access to the IT network to manipulate industrial control devices without requiring physical access, specialized insider knowledge, or advanced tooling. The following versions of Pandu...
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-16232 Check Point SmartConsole Improper Authentication Vulnerability CVE-2026-50522 Microsoft SharePoint Deserialization of Untr...
View CSAF Summary Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product. The following versions of Rockwell Automation 1718-AENTR/1719-AENTR are affected: 1718/ 1719 Ex I/O 3.011 CVSS Vendor Equ...
View CSAF Summary SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerabilities in the components OpenSSL, OpenSSH, and several other packages as described below. Siemens has released a new version of SIDIS Secured SmartPlug and recommends to update to the lat...
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2021-27137 DD-WRT Stack-Based Buffer Overflow Vulnerability CVE-2026-0770 Langflow Inclusion of Functionality from Untrusted Control Sphere...
View CSAF Summary Multiple Siemens products are affected by unquoted search path vulnerability in IAM Client. This could allow an authenticated local attacker to perform privilege escalation. Siemens has released new versions for several affected products and recommends to update...
View CSAF Summary Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Customers are advised to consult and implement the workarounds provided in Palo Alto Net...
View CSAF Summary Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product. The following versions of Rockwell Automation 1734 POINT I/O are affected: 1734 POINT I/O 3.023 CVSS Vendor Equipment Vul...
Our senior consultants monitor the global threat landscape daily. Get proactive protection before the next breach makes headlines.